ecoharvestx.com sales@ecoharvestx.com
EcoHarvest
ECOHARVESTLivestock climate equipment

Climate equipment for livestock and poultry houses.

Poultry · Swine · Cattle

Galvanized cone exhaust fan with wire guard, side view
Cattle barn fan with blue and black blades Framed cooling pad, front view

What we supply

Tunnel ventilation — pad and fan system

Exhaust fans, evaporative pads, and light traps quoted as one design for poultry houses and swine barns. Dark-out houses need traps on both ends.

Tunnel fan front guard

Exhaust fans

Wall-mounted negative-pressure exhaust fans for poultry houses and swine barns. Box, hammer-shutter, and cone types.

Exhaust fan details
Framed cellulose cooling pad

Cooling pads

Cellulose evaporative media, frames, and water distribution for the inlet wall. Pad area is matched to fan capacity so contact time stays in range.

Pad details
Light trap modules stacked

Light traps

Air passages that block daylight at fans and inlets. Required in breeder, layer, and other dark-out houses that run a lighting program.

Trap details
Tunnel ventilation system — exhaust fans and evaporative cooling pads; on dark-out houses, light traps at the fan end

Tunnel ventilation system

Tunnel ventilation: exhaust fans, cooling pads, and light traps specified as one pad-and-fan system.

System details

Cattle barn fans

Cattle barn hanging box fan in operation

Cattle barn fans

Box fans for cattle and dairy barns — hanging or aisle-mounted. Quoted to barn size, stocking, and power. Not a poultry-house tunnel-wall exhaust kit.

Cattle fan details

How tunnel climate is specified

Start from the house, not from a catalog page.

A working tunnel system is a pressure path: inlet area, pad resistance, house tightness, and fan capacity have to add up. Under-sized pad area raises static pressure and cuts fan output. Over-speed through the pad wastes water and wets the house. Light traps add resistance that must be in the fan selection, not added later.

Send house dimensions, bird or livestock type, stocking, local design temperature and humidity, and available voltage. We reply with a practical equipment list and a quotation.

Email a project brief

AirspeedTunnel cooling depends on velocity along the birds or animals, not on mixing fans alone.
Pad face velocityPad area is set so air has contact time to evaporate without choking the fans.
Light disciplineDark-out houses need traps on every daylight opening, including the fan wall.

Who this site is for

Integrators, distributors, and farm operators.

Farm operators

Replace a fan wall, add pad cooling, or close a light leak on an existing house. Tell us what is already installed.

Builders and integrators

Match fans, pads, and traps to a house drawing. We quote configurations, not a single universal kit.

Distributors